Replacement items (a)
The items that should be replaced at the timing of "R-a" (every PM cycle) are as shown below.
Section
Process
related
section
Main charger
Drum/Cleaner
Developer unit
Transfer belt
Fuser unit
RADF
*1: If a part is deformed or damaged, the part must be replaced immediately.
Replacement items (b)
The items that should be replaced at the timing of "R-b" (PM cycle x2) are as shown below.
Section
Developer unit
Toner bag
June 2002 ©TOSHIBA TEC
Item
Ozone filter
Charger wire
Charger wire cleaning pad
Grid
Photoconductive drum
Drum cleaning blade
Drum cleaning brush
Separation finger for drum
Developer material
Toner filter
Transfer belt
Transfer belt cleaning brush
Transfer belt cleaning blade
Fuser roller
Pressure roller
Upper separation finger
Cleaning WEB
WEB pushing roller
Cleaning roller (felt)
Cleaning roller (metal)
Pickup belt
Separation roller
Feed roller
Item
Oil seal (9pcs.)
Toner bag
*1
*1
*1
5-11
e-STUDIO550/650/810 Service Features
Remarks
Remarks