Electrical Connection - Miele PW 5065 OS Operating And Installation Instructions

Washer-extractor
Hide thumbs Also See for PW 5065 OS:
Table of Contents

Advertisement

Installation and connection

Electrical connection

All electrical work should be carried out
only by a suitably qualified and
competent person, in strict accordance
with national and local safety
regulations.
,
Ensure power is not supplied to
the appliance while installation work
is being carried out.
The appliance is supplied with a mains
cable for connection to
440V ~3 phase supply 60Hz
without neutral
The machine is not convertible.
,
The voltage, rated load and fuse
rating are given on the data plate.
Please ensure these match the site
mains supply.
Connection should be made via a
suitable isolator which complies with
national and local safety regulations,
and the on/off switch should be easily
accessible for servicing work.
56
For extra safety it is advisable to install
a residual current device (RCD), with a
trip current of 30 Ma (in accordance
with DIN VDE 0664, DIN VDE 0100
Section 739).
When switched off there must be an
all-pole contact gap of 3 mm in the
isolator switch (including switch, fuses
and relays acc. to VDE 0660.
WARNING:
THIS APPLIANCE
MUST BE EARTHED