(4) Explanation of icons
The air conditioner icons on the Web screen are shown below.
Item
Operation status of air
conditioner group
Operation status of
ventilation equipment group
(Lossnay)
Operation status of
interlocked equipment
Schedule status

2.1.3 Centralized control by integrated software TG-2000A

(1) Features
1 The indoor unit up to 2,000 sets (40 sets of G-50A) can be controlled/monitored.
2 The layout display of air conditioners provides convenience in managing and controlling.
3 Annual schedule can be set (requiring license registration in the optional function).
4 Thanks to the apportioned function of electric power (requiring license registration in the optional function), your PC may collect the electric power
apportioned rate per indoor unit in CSV format.
Then, you can calculate the air conditioning charge per group, block and area by inputting the WHM amount manually or summing up the value of WHM
with the designated PLC (sequencer) and special program software (to count electric charge) or RS-485WHM.
And also, electric (non Air conditioner), gas, water apportioned rate can be collected (In case of PLC and electric power apportioned rate software only).
5 Installing the exclusive software (for general equipment control) on PLC allows monitoring/operating
the air conditioners and system equipment of other makes.
6 The energy conservation/peak-cut control function (optional function requiring license registration
separately) can reduce the energy consumption of air conditioning equipment.
By monitoring power consumption with PLC in addition, the peak-cut control corresponding to the
power consumption can be performed.
G-50A
Power supply unit
PLC (Counting power consumption)
PLC (Controlling general equipment)
HUB
Install the integrated
software (TG-2000A).
Figure 2-3 Outline diagram of integrated soft system composition
1
The accounting block means a block for accounting configured by groups. As for details, refer to page 8.
Operating
Operating
Interlocked equipment operating
Interlocked equipment stopping
Schedule provided
Schedule not provided
Icon
Stopping
Abnormality generated
Stopping
Abnormality generated
Watt Hour Meter (WHM)
with pulse oscillation device
General equipment
(Chiller, pump or the like)
Monitoring, etc.
By installing the integrated software (TG-2000A)
on the PC for centralized control, the operation
status of all air conditioners being managed can
be monitored and controlled.*
license registration in addition, the annual/weekly
schedule function and electric power apportioning
function can be used.
*1 Please refer to section 2,3 for function licence.