Data Field Descriptions
Entry Delay 01
35
00-99 = entry delay time in seconds.
Entry Delay 02
36
00-99 = entry delay time in seconds.
Audible Exit Warning/Quick Exit
37
Exit Warning
0 = no exit warning
sound
1 = provide exit
warning sound
when armed AWAY
Confirmation of Arming Ding
38
0 = no ding
1 = confirmation ding after arming system
2 = confirmation ding after arming from RF button or
RF keypad only
Power Up In Previous State
39
0 = always power up in a disarmed state
1 = assume the system status prior to power-down
DIALER PROGRAMMING (
42: Enter up to the number of digits shown. Enter 0–9, # + 11 for ' * ' ; # + 12 for '#'; # + 13 for a pause
Fields
40,
41,
(2 seconds)
NOTE: Whenever AAV is used, primary (field ✻41) and secondary (field ✻42) phone numbers should be preceded with the call waiting
disable command. Otherwise, there is the possibility of connection of the third party to LYNX during AAV mode.
PABX Access Code
40
Enter up to 6 digits if PABX is needed to access an
outside line.
Primary Phone No.
41
Enter up to 20 digits.
Secondary Phone No.
42
Enter up to 24 digits.
!
All four digits of the Subscriber Account number must be entered in Fields ✻ 43 and ✻ 44. If ten digit format is
selected in ✻ 48 (option 5), all ten digits of the Subscriber Account number must be entered.
Fields
43 and
44:
Enter [
] as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as the first
digit of a 4-digit account number for Nos. 0000–0999. Enter [
CID®) is used. Exit field by pressing [
blank Programming Form for examples of account number entries. If using the paging feature, do not enter a leading 0
in the subscriber account number, and do not use digits A-F anywhere in the number. Some paging systems provide
voice mail capability, which is activated by a leading 0 in the message. Enter digits 0–9; # +11=B; # +12=C; # +13=D; #
+14=E; or # +15=F.
Primary Subs Account No.
43
Enter a four or ten digit account number.
Secondary Subs Account No.
44
Enter a four or ten digit account number.
Quick Exit
0 = no quick
exit
1 = allow quick
exit
40–
50)
] if only 3 digits are used. To clear entries from field, press
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
The system will wait the time entered before sounding alarm upon entering
if system is not disarmed. UL installations: must be set for a maximum of
45 seconds
The system will wait the time entered before sounding alarm upon
entering. UL installations: must be set for a maximum of 45 seconds
Exit Warning: Sound consists of slow continuous beeps until last 5 seconds,
when it changes to fast beeps. The warning sound will end at the
termination of exit delay.
Quick Exit: If enabled, user can restart the exit delay time after arming in
STAY mode by entering the user code and pressing the STAY key, or by
pressing the STAY key if Quick Arm is enabled. This avoids having the
user disarm then re-arm the system after allowing someone to enter or exit
Confirmation of arming is provided by a 1/2 second external sounder "ding"
that sounds when closing report is sent, or at the end of exit delay.
If Option 2 is selected the external sounder "ding" occurs immediately after
the system receives the RF transmission.
When the system powers up armed, an alarm will occur 1 minute after
arming if a zone is faulted, and any bypassed zones will be unbypassed.
Note: If the previous state was armed AWAY or STAY, the system will not
respond to sensor changes for 1 minute, which allows time for sensors such
as PIRs to stabilize. UL installations: must be 1 (power up in previous
state)
If fewer than 6 digits need to be entered, exit by pressing [
entries from field, press
If fewer than 20 digits entered, exit by pressing [
field, press
41
.
Note: Backup reporting (8 attempts are made to the secondary phone
number if no kissoff is received after 8 attempts to the primary
number) is automatic only if there is a secondary phone number
(field
42).
If fewer than 24 digits entered, exit by pressing [
field, press
42
. See backup reporting note for field
paging feature, enter the pager phone number here.
] as the fifth digit if a 4-digit account number (for 3+1,
Enter the primary subscriber account number.
To clear entries from field, press
Enter the secondary subscriber account number.
To clear entries from field, press
–18–
40
.
]. To clear entries from
]. To clear entries from
41. If using the
43
43
.
44
.
]. To clear
or
44
. See

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lynxr-eLynxr24Ademco lynxrAdemco lynxr-enAdemco lynxr24

Table of Contents