56 Enhanced Zone Programming Mode
Delete zone parameters
confirmation
F
0 = discard the delete request
1 = confirm requested delete
Note: If 00 was entered as a zone type in prompt (b),
00 will be retained and system will advance to
prompt (1C).
Enroll mode
0 = advance to the VOICE DESCRIPTOR
IA LC
prompt (1C).
Note: This will save all zone parameters.
1 = enter now and proceed to SERIAL
NUMBER prompt (1b).
Note: Not applicable if the serial number is already
present.
2 = copy the last serial number entered into
local ram.
Note: If this is the 1st zone, none will be in the buffer
and the panel will emit a long tone. Not valid if
serial number is already present.
3 = view existing serial number.
Note: Only if "L" is displayed. If "L" is not displayed,
panel will emit a long beep.
9 = advance to F; delete existing serial
number.
Note: Only if "L" is displayed. If "L" is not displayed,
panel will emit a long beep.
[✻] = advance to the VOICE DESCRIPTOR
prompt (1C). This will save all zone
parameters.
[#] = return to the LOOP NUMBER prompt (E).
Note: In order for all entered parameters to be
accepted, you must advance to the VOICE
DESCRIPTOR prompt (1C).
WWW.DIYALARMFORUM.COM
WWW.DIYALARMFORUM.COM
RF Learning - Two (2) transmissions (2 key depressions) at least 5
seconds apart will be required for BR type devices (device type 5). Two
beeps will sound after the second transmission, confirming that the loop
number and serial number have been learned.
For all other device types, four (4) transmissions are required (fault,
restore and fault, restore). A single beep will sound after the second
transmission confirming that the loop and serial number have been
captured. Following the fourth transmission the system will confirm that
the loop number and serial number have been learned and announce the
Voice Descriptor for the zone, if it is programmed, followed by two beeps.
Press [
] to continue.
Manual Entry - Enter the desired loop number and press [
continue (see the transmitter's Installation Instructions for specific loop
designations).
Note: The loop number can be changed even if the zone has already
been entered. Care should be taken when using this feature as it
has the capability to make zones inoperable by creating a
mismatch of a working serial number/loop number combination.
This should be re-confirmed if the loop number is changed.
"L" indicates that the zone's serial number has already been enrolled.
This function deletes either the serial number or all zone information
that is programmed for the zone.
If "00" was entered in the zone type, the confirmation of the delete
request will delete all information associated with the zone currently
being programmed.
If "0" was entered in the loop number, the confirmation of the delete
request will delete the serial number of to the zone currently being
programmed.
If "L" is displayed, the serial number for this transmitter has already
been entered. It may, however, still be viewed, confirmed (only if in
listen mode), or deleted.
View serial number
Enter "3". Each digit will be redisplayed, and the keypad will beep once
for digits 1-6, and three times for the last digit.
Confirm serial number
The serial number/loop number combination can be confirmed after one
transmission from a BR type device or two transmissions (fault and
restore) from a UR or RF type device. If a transmission is received that
matches the serial number and loop number entered, the system will
confirm the reception by announcing the Voice Descriptor for the zone, if
it is programmed, followed by three beeps, and a "C" will appear on the
display indicating the received serial number and loop number have
been confirmed. No further transmissions will be received.
Delete serial number
The serial number can be deleted by entering "9".
If "L" is not displayed, the serial number for this transmitter has not
been previously entered. You may enter the serial number manually,
copy the previous serial number, return to Prompt (E) or enter the serial
number later using the
–27–
83 Enhanced Sequential Mode.
] to

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lynxr-eLynxr24Ademco lynxrAdemco lynxr-enAdemco lynxr24

Table of Contents