80 Device Programming Menu Mode
The following explains these prompts in detail. The left two columns identify the prompts and list the
available entries. The right-most column provides a further explanation of the entries.
Note: Entering a number other than one specified will give unpredictable results.

Powerline Carrier Device

80
programming
0 = exit mode
1 = enter mode
Device number
01-08 = device number to be programmed
A
0I
[✻] = continue
00 = exit Device Programming mode
Device action
b
aa
0 = No response
1 = Close for 2 seconds
2 = Close and Stay Closed
3 = Continuous Pulse on & off (1 sec ON, 1 sec
OFF)
[✻] = continue
[#] = return to previous prompt
Start event type
et
0 = Not used
C
1 = Alarm
2 = Fault
Start zone list
d
zl
1-3 = zone list number (to be programmed in
field ✻81)
0 = zone list not used for this device
[✻] = continue
[#] = return to previous prompt
Start zone type
01-58 = zone type to start this device action
E
zt
00 = zone type not used for this device
[✻] = continue
[#] = return to previous prompt
Stop zone list
zl
1-3 = zone list to stop this device action
F
0 = zone list not used
[✻] = continue
[#] = return to previous prompt
Stop zone type
zt
01-58 = zone type to start this device action
IA
00 = zone type not used for this device
[✻] = continue
[#] = return to previous prompt
WWW.DIYALARMFORUM.COM
3 = Trouble
[✻] = continue
[#] = return to previous
prompt
(select only those that are applicable)
(select only those that are applicable)
–31–
WWW.DIYALARMFORUM.COM
Entering "1" advances to the next prompt below.
Entering "0" exits mode, upon which this prompt blinks, indicating the
mode is inactive.
Enter device numbers as 2-digit entries.
Enter the 1-digit action (0-3) for the device being programmed (current
action is displayed).
NOTES:
1. If "3" is entered (pulse), only up to 3 different devices can be pulsed
if one of the devices is a siren/horn (X-10 Powerhouse Security
model SH10A). In addition, the siren/horn cannot be manually
activated using the lights on/lights off keypad commands.
2. If using an X-10 Powerhouse Security SH10A siren:
• you must use device action "3."
• you must change the device action default to "3" if using default
table 2 or 4
Enter the 1-digit event type (0-3) to activate the device being
programmed. A zone list must be used in conjunction with an event. If
a zone type/system operation is to be used instead of an event, enter
"0".
If a zone list will be used to start the device action, enter the zone list
number at this prompt.
If a zone type or system operation will be used to start the device
action, enter the appropriate 2-digit code for the device being
programmed (see table that follows).
Choices for zone types
00 = Not Used
04 = Interior Follower
01 = Entry/Exit #1
05 = Trouble Day/Alarm Night 09 = Fire
02 = Entry/Exit #2
06 = 24 Hr Silent
03 = Perimeter
07 = 24 Hr Audible
Choices for system operation
20 = Arming–Stay
33 = Any Alarm (except zt 08) 42 = Sys. Batt. Low
21 = Arming–Away
36 = At Bell Timeout**
22 = Disarm. (Code + OFF)
38 = Chime
31 = End of Exit Time 39 = Any Fire Alarm
32 = Start of Entry Time
40 = Bypassing
** Or at Disarming (which ever occurs earlier)
Note: If an X-10 device has been programmed to ZT05 or ZT07 and *55
has been enabled, the device response will be dependent upon the
selection made in *55 Field "Ln".
If a zone list will be used to STOP, or restore, the device action, enter
the zone list number 1, 2, or 3 (to be programmed in
used, enter "0".
If a zone type or system operation will be used to STOP the device
action, enter the appropriate 2-digit code (see the "ZT" choices listed
above). If not, enter 00.
The display then returns to the DEVICE NUMBER prompt (A) so that
you can enter the next device number to be programmed, or enter [0][0]
to end device programming.
08 = 24 Hr Aux
10 = Interior w/Delay
24 = Silent Burglary
43 = Comm. Failure
52 = Kissoff
58 = Duress
81 mode). If not