Limiters Crossover (Advanced Tab); Limiters Metering (Summary Tab) - Omnia .11 Installation And Operation Manual

Stereo fm audio processor
Table of Contents

Advertisement

Limiters Crossover
Limiters Crossover Menu (Advanced Tab)

Limiters Metering (Summary Tab)

Limiters Metering Screen (Summary Tab)
(Advanced Tab)
The 2 drop-down controls in the Limiters crossover
Advanced tab allow you to modify the crossover
frequency points of the LO (LO to ML) and SL (SL to
LO) limiter bands. The ML to MH, MH to HI and HI to
SH crossover points are not adjustable.
The available LO crossover settings are 320 Hz and 420
Hz.
The available SL crossover settings are 200 Hz, 175 Hz
or 110 Hz.
Similarly to the AGC gain reduction meters, the 6
limiter band gain reduction meters show the amount
of limiter activity from the top down in dB and the
crossover frequencies in use are shown just above
the meters. Likewise, gating activity is indicated by
a bright yellow outline around each gain-reduction
meter.
45