AES/EBU Digital Input, Outputs & AES/EBU External Sync Input
The digital AES/EBU (AES-3) inputs (AES INPUT and AES SYNC IN) use standard balanced 3-pin female XLR
connectors. They accept any sampling rate between 32kHz and 96kHz. No user adjustment of the sample rate is
necessary on the AES-3 input as a high-quality digital sample rate converter is built in.
There are two AES-3 outputs on standard balanced 3-pin male XLR connectors. These provide either an internally
generated output sample rate of 48 kHz or the sample rate can be locked to an external AES/EBU signal applied to
the AES SYNC IN connector or to the AES/EBU input signal. These options are selectable using the "Samp. Rate"
(Sample Rate) setting in the Output menu.
Note: The analog and digital outputs are active simultaneously.

Ethernet / Livewire Connections

NOTE: Network functionality/Setup is not available with the initial software. It will be
made available to you in a future software update.
The RJ-45 10BaseT / 100BaseT Ethernet / Livewire I/O jack
can be used simultaneously for both TCP/IP based remote
control of your Omnia.11 and audio input/output to your
existing Livewire network.
Ethernet 10BaseT/100BaseT Remote and
Livewire I/O