Electrolux E23CS75DSS0 Service Manual page 124

2008 electrolux side-by-side refrigerator service manual
Hide thumbs Also See for E23CS75DSS0:
Table of Contents

Advertisement

124
Section H - Water System
VOLTAGE READINGS AT GREEN COIL OF SECONDARY VALVE
When Ice Maker is Filling:
Voltage at Outlet
120 VAC
100 VAC
100 - 120 VAC
VOLTAGE READING AT YELLOW COIL OF SECONDARY VALVE
When Filling A Glass With Water:
Voltage at Outlet
120 VAC
100 VAC
100 - 120 VAC
VOLTAGE READING AT COIL OF PRIMARY VALVE
When Ice Maker is filling:
Voltage at 0utlet
120 VAC
100 VAC
100 - 120 VAC
100 - 120 VAC
NOTE: You must remember that with the current flowing to the Primary Valve Coil through the Diode,
you are getting 30 cycle instead of 60 cycle current at the coil of the Primary Valve. Because of this,
your volt meter will only read about 1/2 the voltage that is going to the coil. The change in the cycle of
current does not effect the efficiency of an electromagnetic coil.
Voltage at Coil
100 ± 10% VAC
Normal
85 ± 10% VAC
Normal at 105 VAC (Will require use of 50 watt coil)
20 - 76 VAC
Bad connection, Fill Switch, or Heater in Ice Maker.
Voltage at Coil
119 ± 10% VAC
Normal
99 ± 10% VAC
Normal
0 - 90 VAC
Bad connection or bad Fill Switch
Voltage at Coil
56 ±10% VAC
Normal
48 ± 10% VAC
Normal
10 - 43 VAC
Bad connection, Fill Switch, or Heater in Ice Maker
0 VAC
Open Diode (if current is normal at secondary coil)
Figure H10
Figure 2
Figure H10
91