Burner Specification; Operation; Pre-Operational Checks - Stanley BRANDON 60K User Manual

Brandon 60k/80k/100k oil fired cooker
Table of Contents

Advertisement

Burner Input
(kW) Continuous Running
(kW) Cycling
(Btu's) Continuous Running
(Btu's) Cycling
Boiler Output
(kW) Continuous Running
(kW) Mean Cycling
(Btu's) Continuous Running
(Btu's) Mean Cycling
Nozzle
Pressure
(Bar)
(PSI)
Fuel Consumption
(L/Hr) Continuous Running
(L/Hr) Cycling
US Gal/Hr
Continuous Running
US Gal/Hr Cycling
All data are taken under laboratory conditions and may vary in use
Differential Pressure Across the Boiler
Design flow rate through the boiler
Static differential across the boiler
Dynamic pressure differential across the boiler
Note: Design temperature differential across the boiler = 11°C (20°F)
This appliance conforms to the following:
Low Voltage Equipment:
Electromagnetic Compatibility:

PRE-OPERATIONAL CHECKS

(a) Check that the cooker is connected to the mains
electrical supply.
"WARNING THIS EQUIPMENT MUST BE
EARTHED"
(b) Check that all valves in the oil line are open and

BURNER SPECIFICATION

100K
34.2
N/A
116,760
N/A
29.3
N/A
100,000
N/A
o
0.85 80
S (C.E.N) 0.65 80
7.4
107
3.6
N/A
0.95
N/A
72/23/EEC
95/68/EEC
89/336/EEC
92/31/EEC
93/68/EEC

OPERATION

BOILER BURNER
80K
27.7
N/A
94,600
N/A
23.5
N/A
80,000
N/A
o
S (C.E.N) 0.55 80
7.4
108
2.9
N/A
0.77
N/A
38.2 L/min / 8.4 Gpm
52.4 mbar / 21" wg
33 mbar / 13.23" wg
that the filter and oil pump are purged of air.
(c) Check that appliance thermostats are in the off
position.
(d) Check that the boiler and heating system is full
of water and purged of air.
4
COOKER BURNER
60K
100K/80K/60K
21.4
N/A
73,000
N/A
17.6
N/A
60,000
N/A
o
S (C.E.N)
0.5 60
7.1
103
2.2
N/A
0.58
N/A
19.5
4.4
66,875
14,950
2.1
1.2
7,000
4,000
o
S (C.E.N)
7.1
110
2.1
0.47
0.55
0.12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brandon 80kBrandon 100k

Table of Contents