Standard Procedure - Testing For Ashort To Ground On Fuses Powering Several Loads; Standard Procedure - Testing For Avoltage Drop; Wiring/Terminal - Chrysler 300M Service Manual

Chrysler/dodge
Hide thumbs Also See for 300M:
Table of Contents

Advertisement

8W - 01 - 10
WIRING DIAGRAM INFORMATION (Continued)
STANDARD PROCEDURE - TESTING FOR A
SHORT TO GROUND ON FUSES POWERING
SEVERAL LOADS
(1) Refer to the wiring diagrams and disconnect or
isolate all items on the suspected fused circuits.
(2) Replace the blown fuse.
(3) Supply power to the fuse by turning ON the
ignition switch or re-connecting the battery.
(4) Start connecting or energizing the items in the
fuse circuit one at a time. When the fuse blows the
circuit with the short to ground has been isolated.
STANDARD PROCEDURE - TESTING FOR A
VOLTAGE DROP
(1) Connect the positive lead of the voltmeter to
the side of the circuit closest to the battery (Fig. 9).
(2) Connect the other lead of the voltmeter to the
other side of the switch, component or circuit.
(3) Operate the item.
(4) The voltmeter will show the difference in volt-
age between the two points.
Fig. 9 TESTING FOR VOLTAGE DROP
8W-01 WIRING DIAGRAM INFORMATION
SPECIAL TOOLS

WIRING/TERMINAL

TERMINAL REMOVING TOOLS 6932 AND 8638
PROBING TOOL PACKAGE 6807
TERMINAL PICK TOOL SET 6680
TERMINAL REMOVING TOOL 6934
LH