8) Place the blower close to the base of the unit and feed the long red
and black wires through the opening of the base of the unit and the
short red and black wires through the small hole at the base of the
unit.
9) Slide Thermodisc into the bracket on the left side of the rear fi re-
box.
Thermodisc
Braket
11) Mount the blower assembly in position under the base of the stove
and secure with the 2 supplied bolts (2-1/4" #20 hex head)
This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
10
Thermodisc
WARNING: Electrical Grounding Instructions
12) Before re-attaching the rear access panel, the valve wires and the
fan wires need to be connected.
Re-connect the red and grey valve wires.
Connect the fan wires.
13) Slide the Rear Access Panel back into position and secure with 2
screws.
®