11) Attach the bent tube to the regulator and side block
and torque to the proper specification.
12) Secure the whisker to the port retainer with the
screws, spacers and kidney plate removed earlier.
13) Tighten the regulator mount nut and bent tube
attachments.
14) Reinstall the oral nasal and nose block device.
15) Allow 24 hours for the silicone sealant to cure
before diving with the helmet. Test the helmet for
leakage before diving under any conditions and before
every contaminated water dive.
Use a tie wrap to secure the double exhaust whisker
to the double exhaust main body.
WARNING
The exhaust valves used in the double
exhaust system and regulator must be
regularly inspected and replaced when-
ever they show the slightest signs of
wear. If this is not done, leakage into the
helmet and breathing systems may oc-
cur. This can be fatal, depending on the
type of contaminant to which the diver
is exposed.
© ⅯⅯⅩⅡ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 120613005
Completed installation of the double exhaust system.
WARNING
Any helmet / dry suit system must be leak
tested according to the manufacturer's
instructions before EVERY dive in con-
taminated water! The slightest leak may
be produced serious long term disability
or death, depending on the contaminant.
®