Wsiu1 - Serial Interface Board; Wsiu1 Installation; Wsiu Programming - Toshiba DK14 Installation And Maintenance Manual

Strata dk digital business telephone solutions
Table of Contents

Advertisement

WSIU1 - Serial Interface Board

System:
Circuits per PCB:
Interfaces with:
Older Version(s):
The WSIU1 PCB enables the DK14 system to connect to various hardware devices. It does not
have an internal modem and does not support IMDU or RMDS.
Only one WSIU1 can be installed per DK14 system. When installed, the WSIU1 port functions are
identified and enabled automatically when power is turned on. See Program 76-1 for initialized
data.
CO lines that receive Caller ID must be cross-connected to the TC-1041 (MLX-41) Caller ID
interface box. See
The TC-1041 (MLX-41) is available from TCI, Inc., P.O. Box 4087, Huntsville, AL 35815-4087.
Phone (256) 881-4000.
The communication parameters for TTY and Caller ID (WSIU1 SI01 or SI02) ports are:
Data word bits = 7
o
Parity = even
o
Stop bits = 1
o
The communication parameters for SMDR (WSIU SI01 or SI02) are:
o
Data word bits = 8
o
Parity = None
o
Stop bit = 1

WSIU1 Installation

1. Make sure that the power supply switch is Off. See
2. Slide the front edge under the System Frame Ground Bar. Align and insert WSIU connector J4
into the motherboard connector J21, and J3 into J20. Apply firm, even pressure to ensure
proper making of the connectors. Make sure the edge of the WSIU is next to the connector J1
and J2.
3. Remove the "knock-out" from the KSU cover SI01 or SI02 access slot, and store the "knock-
out" in the slots provided in the KSU base. (See

WSIU Programming

Program 03: No assignment is necessary. WSIU1 is automatically enabled when installed and
power is turned On. It is not assigned to a slot.
Program 76-1X-Y: Assigns each installed WSIU1 port to a function. Where X identifies the
WSIU1 port number (1~2) and Y identifies the WSIU1 port function:
o
Y=1, RS-232 TTY (Program 77-1, LED 14 Off)
Strata DK I&M
5/00
DK14
two serial interface ports
SMDR connection for call accounting device
Caller ID Interface Box, Interface for local connection of DKi Admin PC
customer-provided external modem for remote maintenance from a PC with
DKi Admin
none
Figure 1-17
for wiring.
WSIU1 - Serial Interface Board
Figure
1-14.
Figure
1-11.)
DK14 Installation
1-19