DK14 Installation
WSIU1 - Serial Interface Board
o
o
o
o
Program 76-2X-Z: Assigns each installed WSIU1 port to operate at a specified transmission rate.
Where X identifies the WSIU1 Port number (1, 2). Z identifies the WSIU1/port transmission rate
in bits-per-second (bps):
o
o
o
o
Note

WSIU Wiring

Note
1-20
Y=2, SMDR
Y=4, SMDI
Y=6, Caller ID Interface
Y=0, No function - this should be used for any WSIU1 ports that are not used.
Z=1; 9600
Z=2; 4800
Z=3; 2400
Z=4; 1200
The sum of WSIU1 port 1 and port 2 bps rate cannot exceed 9600 bps.
Refer to Chapter 12 – Peripheral Installation, SMDR and TTY for WSIU wiring/