Intercabinet Ground; Ac Power Cabling Installation; Ac Power For One Or Two Cabinets (Wall Mount) - Toshiba DK14 Installation And Maintenance Manual

Strata dk digital business telephone solutions
Table of Contents

Advertisement

DK424 Installation

AC Power Cabling Installation

Intercabinet Ground

Connect intercabinet ground wires (supplied with each cabinet) between cabinets in systems with
two or more cabinets
AC Power Cabling Installation
The system requires an input power source of 50/60 cycles, 115VAC ± 10VAC, and up to 17.5
amps AC to operate. AC power cabling requirements vary, depending on the method of cabinet
installation and the number of cabinets. Refer
Characteristics" on Page 5-4
Some floor-mounted configurations and all wall-mounted configurations require AC outlets,
which must be dedicated to system use, fused, and grounded. To avoid accidental turn off, do not
configure the outlet with an On/Off switch.

AC Power for One or Two Cabinets (Wall Mount)

Refer to the following instructions to install AC power cabling to floor or wall-mounted systems
with just one or two cabinets:
1. Make sure all power supply (RPSU280) switches are in the Off position.
2. If two cabinets are installed and local electrical code allows only one AC power cord from the
system, install the RPSB2 in the bottom cabinet per
3. For AC power cords that will be plugged directly into a wall outlet: Undo the tie wrap that
keeps the cord coiled. Plug female end of the cord into the power supply, and plug the male
end into the wall outlet.
4. For AC power cords that will be plugged into power strips: Do not undo the tie wrap that
keeps the cord coiled. Plug female end of the cord into the power supply, and plug the male
end into the RPSB power strip. Plug the power strip power cord into a wall outlet (see
5-9).
Note
5-30
(Figures 5-21
for electrical power requirements.
Power Supply testing procedures are provided in Chapter 14 – Fault Finding, which
should be referred to if it is suspected that the power supply does not work properly.
and 5-22).
"Summary of Electrical/Environmental
Figures 5-19
and 5-20.
Figure
Strata DK I&M
5/00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dk40iDk424Dk424i

Table of Contents