Toshiba DK14 Installation And Maintenance Manual page 295

Strata dk digital business telephone solutions
Table of Contents

Advertisement

"A"
Front two
screws, left
and right sides
"B"
Back two
screws, left
and right sides
BFIF
Note
RWBF (3-pairs) and BFIF Stands (1-pair) are supplied with floor installation kit BFIF.
Figure 7-18 Floor Mounting Cabinet Installation
Bolt Cabinets to Concrete Floor
1. Mount the DK424i Base Cabinet on
Floor Mount Fixtures (see
and 7-19).Position the Base Cabinet at
the selected installation location.
2. Mark the floor where holes will be
drilled. Move the Base Cabinet prior to
drilling.
Cover the Base Cabinet with a drop
Note
cloth to protect the power equipment
from dust created during drilling.
3. Use a hammer drill to make holes for 3/8-
inch bolt anchors.
4. Install the bolt anchors, with plugs, in the
drilled holes.
5. Using the driving tool and a hammer,
drive each bolt anchor into the floor.
6. Move the Base Cabinet into position on the equipment room floor.
7. Secure the Base Cabinet to the floor using bolts, lock washers, and flat washers.
Strata DK I&M
5/00
RWBFs are used on left and
right sides, wherever indicated
A
B
RWBF
A
B
A
B
A
B
B
A
RWBF
BFIF
Figures 7-17
Figure 7-19 Installation on Concrete Floor
RWBF
A
B
RWBF
A
B
RWBF
RWBF
A
B
A
B
RWBF
BFIF
5007
BFIFs are used on left and
right sides, wherever indicated
Bottom
Cabinet
BFIF
(Floor
mount
fixture)
Concrete
Floor
DK424i Installation
Step 5: Install Reserve Power
Bolt
Lockwasher
Bolt Anchor
Plug
5242
7-33

Advertisement