Assigning Static Module ID Numbers to the Member Switches

This procedure is used to assign a static ID number to a member switch of
the stack. It must be performed on a switch before the cables are
connected to the AT-StackXG Stacking Module.
This procedure assumes that you have already established a local
management session to the device, as explained in "Starting a Local
Management Session" on page 52.
To assign a static module ID number to a member switch, perform the
following procedure:
1. Enter the following command to view the switch's current module ID
assignment:
show stack
An example of the information the command displays can be found in
Figure 23 on page 56.
2. Enter one of the following commands.
If the Stack Mode is Auto, enter this command, where n is the stack ID
number you want to assign the switch:
set stack moduleid=1 newmoduleid=
For example, to assign the switch the stack ID number 2, enter:
set stack moduleid=1 newmoduleid=2
If the Stack Mode is Static, enter this command, where m is the current
stack ID number of the switch and n is the new value:
set stack moduleid=
For example, if the current value of the My ModuleID is 4 and you want
to assign the switch the ID 3, the command would be:
set stack moduleid=4 newmoduleid=3
3. The new module ID number does not take affect until the switch is
reset. Reset the unit with this command:
restart reboot
4. Wait for the switch to reset and afterwards reestablish the
management session by logging in again.