To The Installer; Air Clearance; Electrical Connections - Taylor QS12 Operating Instructions Manual

Hide thumbs Also See for QS12:
Table of Contents

Advertisement

Section 1
This machine is designed for indoor use only.
DO NOT install the machine in an area where
a water jet could be used to clean or rinse the machine.
Failure to follow this instruction may result in serious
electrical shock.

Air Clearance

Clearances from the grill to other surfaces are required
for proper air circulation:
The required minimum clearances from the grill to
combustible construction is: 4" (102 mm) bottom, 3"
(76 mm) rear, and 3" (76 mm) sides.
Bottom:
4 inches (102 mm) minimum
Rear:
3 inches (76 mm) minimum
Sides:
3 inches (76 mm) to combustible
surfaces
0 inches (0 mm) to non-combustible
surfaces;
0 inches (0 mm) between grills in multiple
installations.
Failure to comply with these minimum clearance
requirements will affect grill performance, and
may cause component damage and overheating
of combustible surfaces.

Electrical Connections

The QS Series grills have one electrical connection.
Check the data plate on the grill for voltage, cycle,
phase and electrical specifications. The power
connection is located behind the access line cover on
the front of the grill.
In the United States, this equipment is intended to be
installed in accordance with the National Electrical
Code (NEC), ANSI/NFPA 70--1987. The purpose of
the NEC code is the practical safeguarding of persons
and property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. Compliance therewith and
Models QS12 & QS24

To the Installer

proper maintenance will result in an installation
essentially free from hazard!
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
Stationary appliances which are not equipped with a
power cord and a plug or other device to disconnect
the appliance from the power source must have an
all--pole disconnecting device with a contact gap of at
least 3 mm installed in the external installation.
This equipment is provided with a grounding lug
that is to be properly attached to the rear of the frame
by the authorized installer. The installation location is
marked by the equipotential bonding symbol (5021 of
IEC 60417--1) on the removable panel and the frame.
The proper wire size and fused circuit should be
selected according to grill data label information.
Incoming power must be connected to the terminals
with black characters on a white background, as
shown:
CAUTION: DO NOT ATTEMPT TO USE
THE GRILL DURING A POWER OUTAGE. Grills
require electrical power for operation. In the event of
a prolonged power outage, place the unit in the "OFF"
position.
1
14092
Figure 1
050831
To the Installer

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qs24

Table of Contents