3.1 Starting the machine

The control current outlet (low voltage) should be con-
nected to a control current lead running the length of the
pipes.
Both ends of the low-voltage lead should be connected to
the connection panel on the vacuum cleaner. One lead to
each outlet.
The central vacuum cleaner's power cable must be
connected to a 120 volt mains socket. The appliance is
double-insulated and does not need to be earthed.
Start/stop button
All models have a start/stop button on the front to start and
stop the power unit, Fig. 8. The start/stop button can also be
used when/if you want to use a Nilfi sk utility inlet to vacuum
direct from the machine (if you do not have a Nilfi sk hose
with remote control) or for testing and demos.
Fig. 8
Manual hose
The vacuum cleaner starts and stops automatically. When
the vacuum hose is connected to a vacuum socket, a
metal ring on the end of the hose closes the control circuit
and the vacuum cleaner starts up. Fig. 7. When the hose
is removed from the vacuum socket, the vacuum cleaner
stops.
Wireless handle
If you use a hose with a wireless handle, you can start
and stop the vacuum cleaner using the switch on the
handle, Fig. 9. Wireless handles also have the feature of
adjusting the suction power of the cleaner, using the but-
tons at the hose handle.
Fig. 9
Wireless
2
1
Deluxe
Fig. 10
If you use a hose with an on-off switch, you can start and
stop the vacuum cleaner using the switch on the handle,
Fig. 10
Fig. 11

3.2 Servicing

Always unplug the power cord before doing any
service work!
If suction is poor, it indicates that the fl ow of air through
the machine is restricted. This may be due to the follow-
ing:
• The dust bag is full and should be replaced.
• The fi lter is clogged and should be cleaned.
The vacuum cleaner has a thermal cut-out that trips if the
vacuum cleaner becomes overheated. If this happens -
unplug the main power cord to reset the vacuum cleaner.
Wait 5-10 minutes to allow the machine to cool down.
While you are waiting, check the hose, dust bag and fi lter
to be sure that nothing is blocking the fl ow of air through
the machine. The vacuum cleaner should now start again.
If the cut-out trips again, you need to get a service fi rm to
remedy the fault.
The model Supreme 100 should only be operated with
a dust bag and fi lter installed.