VB14N
5.1 POWER SUPPLY
Power can be supplied to the scanner through the pins provided on the 25-pin connector used for
communication with the host (Figure 41):
The power must be between 10 and 30 Vdc only.
It is recommended to connect pin 1 (CHASSIS) to a common earth ground.
5.2 MAIN SERIAL INTERFACE
The signals relative to the following serial interface types are available on the input/output connector of
VB14N.
If the interface type is not compatible with the current communication handshaking, then the system
forces the handshake to none.
The main interface type and the relative parameters (baud rate, data bits, etc.) can be set using
the Genius™ utility program or the Genius™ based Host Mode Programming procedure.
Details regarding the connections and use of the interfaces are given in the next paragraphs.
VB14N
Vdc
13
25
GND
1
CHASSIS
Earth Ground
Figure 41 - Power Supply Connections
POWER SUPPLY
V+ (10 - 30 Vdc)
VGND
CHASSIS
45