INST ALLA TION ADJUSTMENT MODE

Access to Installation Adjustment Mode

It will be necessary to perform several mechanical adjustments while
in the Installation Adjustment Mode. Open and remove the projector's
top cover in order to gain access to the adjustment points.
To enter into the installation adjustment mode :
Press ADJUST to start up the adjustment mode.
Push the control stick forward or backward to highlight the path
INSTALLATION in the "Adjustment mode" menu and then press
ENTER.
A warning will be displayed on the screen. If you are a qualified and
authorized service person, press ENTER to start up the installation
mode. Otherwise, press EXIT to return.
When entering the installation mode, the projector will automatically
switch to the internal pattern on 15 kHz/50 Hz.
When the password mode is active (see p.5-3), the password will
be asked.
The password contains 4 digits.
Enter the digits with the numeric keys on the RCU or the local
keypad.
Example : password as 2 3 1 9
For each digit entered, a 'X' appears on the screen under the
displayed text 'enter password'.
If the entered password is correct, you get access to the 'Installation
Adjustment Mode'.
If the entered password is wrong, The message "Wrong pass-
word!!!" will be displayed. The projector stays on the previous
selected item.
Factory programmed password :
0 0 0 0

Overview flowchart of the Installation Adjustment Mode

Adjustment Mode
Installation
5975857 BARCOGRAPHICS 1208s 220197
Projector Distance
CRT Projection Angle Adjustment
ADJUSTMENT MODE
Select a path from
below:
GUIDED
RANDOM ACCESS
INSTALLATION
SERVICE
IRIS
WARNING
RISK OF ELECTRICAL SHOCK
NO USER ADJUSTABLE PARTS
INSIDE
THE FOLLOWING
INSTALLATION MENUS
ARE RESERVED TO,
AND TO BE PERFORMED ONLY
BY BARCO PERSONNEL, OR
BARCO AUTHORIZED DEALERS
IF QUALIFIED, PRESS
<ENTER> TO CONTINUE, OR
IF NOT, <EXIT> TO RETURN.
Optical Lens Focusing
Scheimpflug Adjustment

Installation adjustment mode

enter
password
xxxx
197
enter
password
xxxx
Raster Centering
197