Non-Registered Parameter Number (Nrpn); Registered Parameter Number (Rpn) - Novation ReMOTE SL COMPACT User Manual

Os 4.1 and automap universal 2.0
Hide thumbs Also See for ReMOTE SL COMPACT:
Table of Contents

Advertisement

Name: This setting can be found on the second page of control settings so press the PAGE UP button to access it. Here
you can set the name for the control that appears on the SL Compact display. The control name can be a maximum
of 8 characters long. To enter a character, first use the encoders or buttons in line with the '<' and '>' symbols on the
display to move the cursor to where you want to enter the character. Then, use the buttons in line with 'Upper', Lower'
and 'Punctu' / 'Number' to select the type of character you want to enter (upper case, lower case, punctuation or number).
Note that repeated presses of button 5 will switch between 'Punctu' and 'Number'. Finally, use the encoder or buttons
in line with 'CHAR' to select the character you want to enter. If you want to enter a space, select 'Punctu', as the first
punctuation character is a blank space.
NON-ReGISTeReD PARAMeTeR NUMBeR (NRPN) –
The DispType, LowVal, HighVal, Ports, MidiChan, BtnType and Name settings are the same as for Control Change (CC)
so see the previous section for information on these settings.
NRPN lsb (Non-Registered Parameter Number Least Significant Byte): This allows you to set the NRPN lsb value for
the control to a value from 0 through 127.
NRPN msb (Non-Registered Parameter Number Most Significant Byte): This allows you to set the NRPN msb value
for the control to a value from 0 through 127.
You can toggle display format of the NRPN lsb and NRPN msb setting between decimal and hexadecimal by pressing and
holding MENU and then pressing the ENCODER GROUP A SWITCH.
ReGISTeReD PARAMeTeR NUMBeR (RPN) –
The DispType, LowVal, HighVal, Ports, MidiChan, BtnType and Name settings are the same as for Control Change (CC)
so see that section for information on these settings.
RPN lsb (Registered Parameter Number Least Significant Byte): This allows you to set the RPN lsb value for the
control to a value from 0 through 127.
RPN msb (Registered Parameter Number Most Significant Byte): This allows you to set the RPN msb value for the
control to a value from 0 through 127.
You can toggle display format of the RPN lsb and RPN msb setting between decimal and hexadecimal by pressing and
holding MENU and then pressing the ENCODER GROUP A SWITCH.


Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents