1 TROUBLESHOOTING FOR THE HARDWARE
12
Close the lower cover of the Saddle Stitch Finisher.
Test stapling starts automatically.
Test stapling is necessary to prevent void stapling. Note that the test stapling starts automatically when the two
requirements in step 11 are met with the lower cover of the Saddle Stitch Finisher closed. If the test stapling
does not start, make sure to check the two requirements again. Then open and again close the lower cover of
the Saddle Stitch Finisher.