Item
Phenomenon
6
Saw blade runs too
fast. Saw blade
revolution exceeds
-1
4,180 min
or it is
unstable.
Overload protection
7
circuit continuously
functions.
Laser marker does not
8
light.
(Only Model C 10FSH)
Laser light is poor or
9
strong.
(Only Model C 10FSH)
Cause (s)
a Conroller (pickup) is
out of position.
b Controller failure
c Armature fan is bent
or partially broken.
a Power supply voltage
is lower than rated
voltage.
b Controller failure
a Improper wiring
b Switch failure
c Switching power
supply failure
d Laser marker failure
a Switching power
supply failure
b Laser marker failure
--- 69 ---
Factory
Inspection, repair or adjustment
standard
• Check the position of the
------
Controller [151] referring to
"11-4. Wiring Diagram".
• Replace the Controller [151].
------
• Repair the bent fan.
------
• Replace the Armature Ass'y
[177].
• Same as item 5-(a).
------
• Replace the Controller [151].
------
• Check the wiring.
------
• Check the Switch [156] for
------
conductivity.
• Replace the Switch [156].
• Check the Switching Power
------
Supply [144] for conductivity,
input and output referring to
"11-4. Wiring Diagram".
• Replace the Switching Power
Supply [144].
• Replace the Laser Marker [99].
------
• Same as item 8-(c).
------
• Same as item 8-(d).
------

Hide quick links: