Minimum Clearances - Heatscope ZERO Original Installation And Instruction Manual

Electric radiant heater for well covered/protected indoor and outdoor areas
Table of Contents

Advertisement

Available languages

Available languages

EN

7. Minimum clearances

The dimensions given are minimum values and may differ from the local building and fire regula-
tions. These must be observed and complied with in any case.
The illustrated installation surfaces must comply at least with fire protection class A2.
Please note: The HEATSCOPE® ZERO fulfills IP protection class 4 (IP­X4) for ceiling mounting and IP
protection class 0 (IP­X0) for wall mounting.
Vorgeschriebene Abstände zu brennbaren Montageflächen:
A
min. 12 inch/30cm to wall
min. 3 inch/6 cm to another HEATSCOPE® ZERO
B
min. 12 inch/30cm
C
min. 32 inch/80 cm to furniture below the HEATSCOPE® ZERO
D
min. 3 inch/210 cm
E
min. 3 inch/6 cm to combustible surfaces
(MHS­DAHS4 madatory)
F
min. 8 inch/20 cm
G
min. 6 inch/12 cm
(MHS­WH45, MHS­WHSL or MHS­DAHGMS madatory)
B
A
B
A
D
A
E
C
F
G
D
Protect from
wind and drafts.
Do not
use force.
Protect from
moisture and
humidity.