Hardware installation
All chassis: Firmware problem
FortiGate-5001C STA (status) LED is flashing during system operation
FortiGate-5001C Security System Guide
01-400-181221-20121130
http://docs.fortinet.com/
To correct this problem power down and then restart the chassis. If you are operating a
FortiGate-5000 series chassis you can power down and then restart the chassis without
removing FortiGate-5000 series components.
If the FortiGate-5001C board is receiving power and the handles are fully closed, and you
have restarted the chassis and the FortiGate-5001C still does not start up, the problem
could be with FortiOS. Connect to the FortiGate-5001C console and try cycling the
power to the board. If the BIOS starts up, interrupt the BIOS startup and install a new
firmware image. If this does not solve the problem, contact Fortinet Customer Service
and Support.
Normally, the FortiGate-5001C STA (status) LED is off when the FortiGate-5001C board is
operating normally. If this LED starts flashing while the board is operating, a fault
condition may exist. At the same time the FortiGate-5001C may stop processing traffic.
To resolve the problem you can try removing and reinserting the FortiGate-5001C board
in the chassis slot. Reloading the firmware may also help.
If this does not solve the problem there may have been a hardware failure or other
problem. Contact Fortinet Technical Support for assistance.