Procedure 5 - Program the Lock for Tamper Time
Parameters
You can set a Tamper Time Wrong Tries parameter referring to the
number of times the wrong code can be entered before the lock goes
into Tamper Shutdown Mode.
For example, if you program the lock to accept three wrong tries, the
lock will tolerate three wrong entries, staying locked but providing visual
feedback (see visual message chart in rear section). After that, it will go
into a Tamper Shutdown Mode and remain locked until the end of the
Tamper Shutdown Time period - the length of that period is configured in
Steps 1a through 1 c below.
Required User Level: Master, Manager
1. Set the tamper time for the period of time during which the
keypad will remain inaccessible after the specified number
of wrong Access Codes are entered
a. Put the lock into Pushbutton Programming Mode.
b. Enter the code as follows - 006#TT# (TT is seconds - 00 to
90 seconds).
c. Example of Complete Entry: 006#30#. (for 30 seconds)
2. Enter the code as follows: 007 #TT# (TT is number of wrong
entries - 03 to 09), let's use 03 for example.
a. Example of Complete Entry: 007#03#.
b. Enter another # to indicate the end of programming.
c. The lock will stay locked after three wrong entries for the
length of time you select in the steps below, even if a valid
code (including the Master or a Manager Code) is entered
after the three wrong codes. Only the mechanical key
override will open the lock during the lockout period.
d. Enter another # to indicate the end of programming.
In this example, the lock will now remain locked out for 30 seconds after
three wrong Access Codes have been entered. No codes, even valid
ones, will work in the lock until that time period has elapsed. During this
tamper shut down period, the lock will flash the red LED once every 10
seconds
10
Procedure 6 - Programming the Lock for Keypad Buzzer
Volume
You might want to adjust the volume of the Keypad Buzzer depending
on where the lock is located - a noisy or quiet area.
Required User Level: Master, Manager
1. Put the lock into Pushbutton Programming Mode.
2. Enter the code 008#VV# (where VV is a scale of volume from
00 to 03; 00 = off; 01 = Low; 02 = Normal; 03 = High).
3. Example of Complete Entry: 008#02#.
4. Enter another # to indicate the end of programming.
5. The lock will now sound the buzzer at the desired volume
Normal, until you change it.

Users - General Information

1. Master and Manager Codes can do two different things:
• Open the door by entering the Access Code without # signs.
• Put the lock into Pushbutton Programming Mode by entering
# before and after their Access Code.
2. Each user (Manager User, Service User or Access User) occupies
one of the available 100 locations in the user table.
3. By default, user 000 is the Master User.
4. Users have a 15-second period to enter the entire key sequence,
and 5 seconds between pressing each pushbutton number. If
they pause longer than 5 seconds between each pushbutton
pressed, or exceed the 15-second period to enter the total
sequence, the lock:
• aborts the current programming sequence
• automatically exits the programming state
• sends the user a 'Keypad Timeout' feedback message