12. CHANGING FUNCTIONS USING THE DIP SWITCHES
12. CHANGING FUNCTIONS USING THE DIP SWITCHES
12-1.Operation panel DIP switches
Switch
DIPA-1
DIPA-2
DIPA-3
DIPA-4
DIPA-5
DIPA-6
DIPA-7
DIPA-8
12-2.Setting the presser mode
Through the combination of DIP switches A-1 and A-2 on the operation panel, presser motions can be set as
follows:
DIPA-1
DIPA-2
—
—
ON
—
—
ON
ON
ON
44
q
0175Q
Presser does not automatically lift after sewing
is completed.
Two-pedal mode is available.
User program mode is available.
–
The presser does not rise automatically when a split is found.
Displays the enlargement/reduction ratio in millimeter units instead of as a
percentage. (After changing this setting, be sure to carry out the auto-clear
operation by referring to page 41.)
Enlargement of pattern size is not available.
Program number is fixed.
Pedal specifications
Single pedal
Single pedal
Two pedals
Two pedals
KE-430B, 431B, 432B, 433B
The functions shown in the table below can be
changed by means of these DIP switches q.
* All DIP switches are set to OFF at the time of ship-
ment.
NOTE:
Always turn off the power before setting the DIP
switches.
Motion when set to ON
Raising the presser at the sewing end
Presser is raised automatically.
Presser is raised by pressing the pedal.
Presser is raised automatically, then it is lowered by
pressing the pedal.
Presser is kept lifted while the pedal is pressed.
See "12-2. Setting the presser
mode"
0176Q