Checking The Input Voltage; Clearing All Memory Settings - Brother KE-430B Instruction Manual

Electronic lockstitch bar tacker; electronic lockstitch belt loop bar tacker; electronic lockstitch eyelet buttonhole end bar tacker; electronic lockstitch decorative pattern tacker
Hide thumbs Also See for KE-430B:
Table of Contents

Advertisement

10-15. Checking the input voltage

r
e
Specifications
200V
220V
230V
100V
380V
400V
415V
1. Turn on the power switch.
2. Press the SELECT switch q until the Y-SCALE indicator w illuminates.
3. While pressing the TEST switch e, press the RESET switch r.
4. If the input voltage is normal, the input voltage conditions will be shown in the display window t as
indicated in the table above.
5. Press the TEST switch e again to return the display to the normal condition.

10-16. Clearing all memory settings

If the sewing machine stops operating normally, the cause may be that an incorrect memory setting may have
been made by means of the memory switch, for instance. In such cases, carry out the following procedure to
clear the memory, and also check the DIP switch settings.
[ Method ]
While pressing the RESET switch, turn on the power. This will clear all of the memory setting.
NOTE
This operation causes all settings stored in memory such as memory switch and user program settings to be cleared.
If the optional emergency stop switch has been installed, you should reset memory switch No. 10 to ON.
POWER
w
R E S E T
T E S T
BOBBIN.WIND
Display
[090 - 110]
[100 - 120]
"100" is displayed when the input voltage is 200 V.
[105 - 125]
"110" is displayed when the input voltage is
[100 - 120]
100V (for 100-V spece.), 380V (for 380-V spece.),
400V (for 400-V spece.)or 415V (for 415-V spece.).
KE-430B, 431B, 432B, 433B
PROGRAM NO.
P
P1
X - SCALE
P3
Y - SCALE
SPEED
COUNTER
S E L E C T
q
Notes
10. STANDARD ADJUSTMENTS
P2
P4
t
0582Q
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ke-432bKe-431bKe-433b

Table of Contents