E. Adjustments
1. Float level adjustment
Measure the distance from the bottom of
the float to the float bowl gasket surface.
Bend the tongue on the float arm if any
float level adjustment is necessary. Both
floats must be at the same height. If the
fuel level is too high, a rich air/fuel mix-
ture will occur. If too low, a lean mixture
will result.
A . 24+1 m m (0.94f0.04 in1
Tongue
- 3 7 -