FortiSwitch-5003B system

About the SH1 and SH2 LEDs

FortiSwitch-5003B System Guide
01-400-134822-20120216
http://docs.fortinet.com/
Table 3: FortiSwitch-5003B front LEDs (Continued)
LED
State
Green
B1 and B2
Flashing
Green
Off
Link/Act
Solid
(Left
Green
LED)
Blinking
Green
MGMT
Off
Speed
Green
(Right
Amber
LED)
Off
The unlabeled interface beside the MGMT interface is not used.
Blue
Flashing
Blue
IPM
Off
SH1 and SH2 are base channel interfaces that can be used to connect the
FortiSwitch-5003B board to the chassis shelf managers over the chassis backplane. The
SH1 and SH2 LEDs indicate the status of the connections between the
FortiSwitch-5003B board and the shelf manager.
• In most chassis if a FortiSwitch-5003B board is installed in slot 1 the SH1 LED will
light if the board can communicate with the shelf manager in shelf manager slot 1 and
the SH2 LED will light if the board can communicate with a shelf manager in shelf
manager slot 2.
• In most chassis if a FortiSwitch-5003B board is installed in slot 2 the SH1 LED will
light if the board can communicate with the shelf manager in shelf manager slot 2 and
the SH2 LED will light if the board can communicate with a shelf manager in shelf
manager slot 1.
Description
The correct cable is connected to the base channel
interface and the connected equipment has power.
Network activity at the base channel interface.
No link is established.
Indicates this interface is connected with the correct
cable and the attached network device has power.
Indicates network traffic on this interface.
No Link
Connection at 1 Gbps.
Connection at 100 Mbps.
Connection at 10 Mbps.
The FortiSwitch-5003B is ready to be hot-swapped
(removed from the chassis). If the IPM light is blue and no
other LEDs are lit the FortiSwitch-5003B board has lost
power
The FortiSwitch-5003B is changing from hot swap to
running mode or from running mode to hot swap. This
happens when the FortiSwitch-5003B board is starting
up or shutting down.
Normal operation. The FortiSwitch-5003B board is in
contact with the chassis backplane. (If the chassis does
not contain an operating shelf manager, this LED being
off just indicates normal operation.)