7. Calibrating the T-bar
After a firmware update of the switcher it will be necessary to re-calibrate the T-Bar to get it working correctly.
1.
Move the T-Bar to its lowest position.
2.
Power OFF the SE-2800 switcher.
3.
Press and hold down button 1 on both the Program and
Preset rows of the switcher's keyboard.
4.
Power ON the SE-2800 switcher while still holding down
the buttons in step 3.
The switcher will start but the keyboard lights will remain
5.
dead except for the T-Bar progress LEDs. When these
LEDs flash ON and OFF release the buttons from step 3.
6.
Move the T-Bar to almost its top position (2-3mm away)
and then press the CUT button.
Move the T-Bar back to almost its lowest position (2-
7.
3mm away) and then press the AUTO TAKE button.
8.
To exit the calibration procedure press the CLOCK button.
9.
Ensure the TIMER button is OFF.
10. Test the T-Bar.
If necessary change the T-Bar Mode in the OSD MENU
options.