8-4. Removing the Electrical Component Box

(1) Remove the temperature / humidity sensor from the
sensor plate.
(2) Remove the operation box of the main body.
(3) Remove the electrical component box pad plate.
(4) Pull out the fan motor lead wire, upper / lower flap
motor lead wire and UV antibacterial filtration unit
lead wire from the bottom of electrical component
box.
(5) Disconnect all the connectors.
(6) Remove 2 screws and the cable holding plate.
Remove the inter-unit cable.
Temperature /
Humidity sensor
(Release the tabs.)
Tab
Operation box
(Release the tab.)
Electrical component
box pad plate
(Release the 2 tabs.)
Screw
Cable holding plate
Inter-unit cable
Hook
(
Pull the hook forward to
pull out all connectors.
UV antibacterial filtration unit connector
31
Tab
)
Sensor plate
Electrical
component box
Electrical
component box
Fan motor connector
Upper / lower flap
motor connector
(
)
Disconnect from
the P.C.Board.

Hide quick links: