4. REFRIGERANT FLOW DIAGRAM
4-1. Refrigerant Flow Diagram
Indoor Unit
SAP-KRV96EHDS
SAP-KRV126EHDS
Indoor unit
Insulation of Refrigerant Tubing
IMPORTANT
Because capillary tubing is used in the outdoor unit, both the
wide and narrow tubes of this air conditioner become cold. To
prevent heat loss and wet floors due to dripping of
condensation, both tubes must be well insulated with a
proper insulation material. The thickness of the insulation
should be a min. 8 mm.
CAUTION
Wide tube
O.D.
9.52 mm
(3/8 ")
Narrow tube
O.D.
6.35 mm
(1/4")
After a tube has been insulated,
never try to bend it into a narrow
curve because it can cause the tube
to break or crack.
Outdoor Unit SAP-CRV96EHDS
SAP-CRV126EHDS
Outdoor unit
Wide tube
service
valve
Muffler
Narrow
tube
service
valve
Strainer
Thickness:
Min. 8 mm
15
Accumulator
4-way
valve
Capillary
tube for
split flow
Electric
expansion
valve
M
Insulation
Wide tube
Cooling cycle
(Defrosting cycle)
Heating cycle
Thickness:
Min. 8 mm
Narrow tube