8-2. Removing and Mounting the Drain Hose

(1) Before removing the drain hose, check the location of
the drain cramp at the end of the hose.
Turn the hose counterclockwise to remove the drain
cramp from the stopper and pull the hose out.
(2) To mount the drain hose, insert the hose all the way
into the outlet of the drain pan with the drain cramp
face down.
Then, put it in place so that the drain cramp is placed
beneath the stopper.
After mounting it, be sure to check that the drain hose
is firmly mounted.

8-3. Removing the Grill

(1) Fully open the front panel. Widen the arm while
holding the front panel adjacent to the arm, pulls the
front panel and remove it.
(2) Remove the lower left cover.
(3) Remove the screw on the top right of the main body.
Also, remove the screw found when the screw cover
is opened.
(4) Remove 2 screws on the upper part of air outlet.
Push 3 tabs on the top of grille and remove it.
(5) Pull the grille forward and remove it.
Stopper
Drain cramp
Stopper
Drain hose
Ture the hose
Front panel
Arm
Lower left cover
Lower left cover
2 screws on the upper
part of air outlet
* Refer to the "7-5. Remove the grill to Install the
Indoor Unit" to install the grille.
30
Ture the hose
Drain hose
Drain cramp
3 tabs
Flap
Screws
Screw cover
Stopper
Drain cramp
Drain hose
Grill
Screw