2-2. Major Component Specifications

2-2-1. Indoor Unit
Indoor Unit
SAP-KRV96EHDS
Control PCB
Part No.
Controls
Control Circuit Fuse
Remote Control Unit
Fan
Type
Q'ty ... Dia. and Length
Fan Motor
Type
Model ... Q'ty
No. of Poles
Rough Measure RPM (Cool / Heat)
Nominal Output
Coil Resistance
(Ambient Temp. 20 °C)
Safety Device
Type
Over- Current Protection
Over-Heat Protection
Run Capacitor
Flap Motor
Type
Model
For Upper Flap
For Lower Flap
Rating
Coil Resistance
(Ambient Temp. 25 °C)
Panel Motor
Type
Model
Rating
Coil Resistance
(Ambient Temp. 25 °C)
Heat Exchanger Coil
Coil
Rows
Fin Pitch
Face Area
mm
W
Ohm
Micro F
VAC
Ohm
Each Pair of Terminal : 70 +/- 7%
Ohm
Each Pair of Terminal : 70 +/- 7%
Aluminum Plate Fin / Copper Tube
mm
m
2
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
8
CB-KRV96EHDS
Microprocessor
250V 3.15A
RCS-6MHVPUSW4E
Cross-Flow
1 ... D85 / L551
DC Motor
SIC-39CVL-D847-3-A ... 1
8
1,550 / 1,600
30
-
Internal Controller
Yes
Yes
-
-
Stepping Motor
MP24Z1
MP24Z1
DC 5V
Stepping Motor
MP24Z5
DC 5V
2
1.2
0.175