Minimum Heart Extension Requirements - Enerzone Solution 2.5-ZC Installation And Operation Manual

Us environmental protection agency phase ii certified wood fireplace
Hide thumbs Also See for Solution 2.5-ZC:
Table of Contents

Advertisement

Thermal Characteristics of Common Floor Protection Materials*
MATERIAL
®
Micore
160
®
Micore
300
®
Durock
®
Hardibacker
®
Hardibacker
500
®
Wonderboard
Cement mortar
Common brick
Face brick
Marble
Ceramic tile
Concrete
Mineral wool insulation
Limestone
Ceramic board (Fibremax)
Horizontal still air** (1/8")
* Information as reported by manufacturers and other resources
** For a 1/8" thickness. You cannot «stack» horizontal still air to accumulate R-values; you
must separate each layer of horizontal still air with another non-combustible material.

6.3.2 Minimum Heart Extension Requirements

The hearth extension floor area must extend at least 16" (41 cm) in front of the hearth (A)
and at least 8" (20 cm) on each side of the door opening (D). The joint between the hearth
extension and the fireplace hearth needs to be made of non-combustible material such as
sheet metal (not included).
Solution 2.5-ZC Fireplace Installation and Operation Manual
CONDUCTIVITY (k)
PER INCH
0.39
0.49
1.92
1.95
2.3
3.23
5.00
5.00
9.00
14.3 – 20.00
12.5
1.050
0.320
6.5
0.450
0.135
RESISTANCE (R) PER INCH
THICKNESS
2.54
2.06
0.52
0.51
0.44
0.31
0.2
0.2
0.11
0.07 – 0.05
0.008
0.950
3.120
0.153
2.2
0,920**