Fault Indicators - Asko TD60 Service Manual

Tumble dryers
Hide thumbs Also See for TD60:
Table of Contents

Advertisement

Service Manual TD60.C

Fault indicators

Error message
Over Flow
Max program
time
Clean fi lter
Clean condenser
Thermistor fault
Insert fi lter
15
Cause
• A micro switch is opened when a full conden-
sed water tank is detected. Detection begins 30
seconds after the programme starts. If the micro
switch
is open >30 seconds the programme cycle is
stopped.
• The programme cycle time exceeds 200 minutes.
The cycle is stopped and the programme is reset.
• High ambient temperature combined with low
heater output and low drying temperature causes
condensation to form.
• Poor condensing due to blocked external air.
• Indicated when the air fl ow and temperature do
not match.
• Displayed automatically every 100 cycles.
• Displayed if the machine has indicated "Clean
fi lter" twice in a row.
• Thermistor circuit open.
• Thermistor malfunction.
• The fi lter is not correctly inserted in the lint fi lter
holder, which means the magnet in the lint fi lter
cannot trigger the sensor in the lint fi lter holder.
Action
• Check that the customer has emptied the tank and
restarted the machine.
• Clean hoses and check voltage and resistance of
drainage pump.
• Check that the fl oat has not got "stuck" and check the
function of the micro switch.
• Tried spinning at a higher speed.
• Had the machine switched off for 30 minutes before
restarting.
• Good ventilation in the room.
• Ensure that the external air has free passage.
• Clean the fi lter.
• Clean condenser and fi lter.
• Clean other air passages.
• Check the thermistor.
• Properly insert the lint fi lter in the lint fi lter holder.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Td60.c

Table of Contents