(3) Set the plug in the housing A2 of the hood and fix the aluminum tape with a clamp.
(4) Set the two connector lock screws and put the housing B2 there to complete the connector.
♦ How to connect and disconnect a connector
• When you connect the connector, be sure to hold the connector and insert it completely. When you have inserted the connector,
tighten the two lock screws with the Phillips screwdriver.
• When you disconnect the connector, loosen the two lock screws and pull out the lug of connector hood straight. If it is hard to pull
out the connector, hold the controller tightly and pull out it.
Phillips screwdriver
Lock screw
Example of grounding a shielded wire at the controller side:
ID controller
Lock screw (2-M2.6)
Housing A2
Housing B2
Cable clamp
Correct Usage
• To prevent an operation error, ground the shielded wire
Host computer
either at the controller side or the host computer side.
(This figure shows an example of grounding it at the con-
troller side.)
• Short-circuit the RS pin and CS pin inside the connector.
3-1 Controller