• Crimp terminal for terminal
M3 self-up screws are used for the terminal.
For a crimp terminal, use the terminal below.
Tightening torque should be approximately 0.6 N•m.
Take care that the input voltage does not exceed the maximum impressed voltage (26.4 V). Otherwise, a trouble may
occur in devices.
3-1-6-3 Wiring Output Signal
• Crimp terminal for terminal
M3 self-up screws are used for the terminal.
For a crimp terminal, use the terminal below.
Tightening torque should be approximately 0.6 N•m.
(For M3)
Correct Usage
+
DC Power
Relay
Supply
-
(For M3)
V 6 7 0 - CD1 D
V670-CD1D-V1
ID
External
I/O Unit
RST
OUT1
OUT2
O.COM
/IN
OUT1
OUT2
O.COM
3-1 Controller
3-11