2N EntryCom User And Service Manual page 35

Door entry system
Table of Contents

Advertisement

Parameter Parameter Name Range
Count of rings
before incoming
911
call answering
Max. call duration
912
Log-in timeout
913
Hang-up time
915
between calls
Code lock mode
921
Buttons replaced
922
by keypad
Telephone mode
923
Tone dialling
924
during call
Microphone
931
power-up level
Automatic
932
response speed
Reception volume
933
Transmission
934
volume
Message volume
935
Beeping volume
936
DTMF hearing
937
(side tone) volume
Loudspeaker
938
volume
Minimum conti-
941
nuous tone time
Minimum busy tone
942
period
Maximum busy tone
943
period
Maximum tone-
944
space difference
Minimum count of
945
busy tone periods
Minimum ringing
951
tone time
Minimum long
952
space time
Maximum long
953
space time
Count of ringing
periods
954
If the preset count of periods is exceeded and automatic dialling is enabled, another attempt
follows. In the event of Automatic Dialling without Confirmation, the ringing tone is recognised
and ends before the preset count of periods is exhausted; the call is regarded as successful.
Maximum timeout for
961
pressing the next digit
Default
1-99
2
1-99
12=120s
1-99
3
5-99
15 = 1.5s
0-1
1 = enabled
0-1
0 = disabled
0-1
0 = disabled
0-1
0 = disabled
0-3
2
0-3
2
0-15
7
0-15
7
0-15
7
0-12
12
0-3
3
0-15
7
10 - 99
20 = 2s
0-255
8 = 0.08s
0-255
70 = 0.7s
0-255
10 = 0.1s
2-9
4
1 - 200
50 = 0,5 s
5 - 100
10 = 1 s
10 - 100
60 = 6 s
1 - 99
10
1-9
5 s
35
Note
Warning!!! No connection is
established if a higher value is
entered than is allowed by the
PBX ringing timeout!!!
Range of 10s-990s
3 = 30 seconds
0 = disabled
1 = enabled
For details on these functions
see the Keypad Description.
0 = Maximum microphone
sensitivity
3 = Maximum response speed
15 = Maximum reception volume
15 = Maximum transmission volume
15 = Maximum message volume
12 = Maximum tone volume
3 = Maximum DTMF volume
15 = Maximum loudspeaker volume
If the tone is longer,
EntryCom hangs up.
These parameters control the
busy tone detection. They are
used for call termination and
automatic dialling.
2
)
The longest ringing period
space must be in the interval
between parameters 952 and
953.
If the preset count of periods is
exceeded, the call is terminated
During password entering, etc.
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neowave entrycom

Table of Contents