Sartorius CB Operating Instructions Manual page 18

Cb series counting scales
Table of Contents

Advertisement

Example 2:
Counting parts into a full container
Settings: (changes in factory settings required for this example)
Autotare when the [START] is key is pressed: Off (Code 3. 7. 1)
Step
1. Turn on scale, if power is off.
2. Place empty container
on scale and tare.
3. Place full container on scale
and initialize counting.
4. Set reference sample quantity;
in this example, turn selector
to "20".
5. Remove selected quantity of
reference parts from
container.
6. Save reference piece count.
The scale now calculates
the number of parts and
displays the piece count.
7. Print piece count.
If you have selected
"nRef" and "wRef" in the menu,
these lines will be printed:
8. Unload scale
9. Repeat counting starting from step 6, if desired.
18
Press key
Display/Printout
[ON/OFF]
[TARE]
+ 267.3 g
[START]
+ 267.3 SAMPLE
Brief display of:
+ 249.1 g
+ 249.1 SAMPLE
[OK]
+ 274 pcs
+ 249.1 + 0.9100
[PRINT]
nRef
wRef
Qnt
N
T
G#
0.0 g
NET
NET
ref 20
NET
NET
+
20
+
0.9100 g
+
274 pcs
+
249.1 g
+
50.0 g
+
299.1 g
0 pcs
NET

Hide quick links: