Table 3-1
Problem
Beeper Indications
The scanner emits frequent
beeps.
Scanner emits low/high/low
beeps.
Scanner emits low/high
beeps.
Scanner emits low/high/low
beeps.
Scanner emits
low/high/low/high beeps.
Scanner emits high/low
beeps.
Scanner emits
high/high/high/low beeps.
Scanner emits four long low
beeps.
Scanner emits four short high
beeps (USB only).
Possible Causes
No power to the scanner.
Incorrect host interface cable is used.
Interface/power cables are loose.
ADF transmit error.
Invalid ADF rule is detected.
Input error, incorrect bar code or
Cancel bar code was scanned.
The Code 39 buffer was erased or
there was an attempt to clear or
transmit an empty buffer.
Out of host parameter storage space.
Out of memory for ADF rules.
The scanner is buffering Code 39
data.
RS-232 receive error.
A transmission error was detected in
a scanned symbol. The data is
ignored.
Scanner has not completed
initialization.
Possible Solutions
Check the system power. If the
configuration requires a power supply,
re-connect the power supply.
Verify that the correct host interface cable
is used. If not, connect the correct host
interface cable.
Check for loose cable connections and
re-connect cables.
Refer to the Advanced Data Formatting
Programmer's Guide, p/n 72-69680-xx, for
information about ADF programming.
Refer to the Advanced Data Formatting
Programmer's Guide, p/n 72-69680-xx, for
information about ADF programming.
Scan the correct numeric bar codes within
range for the parameter programmed.
Normal when scanning the Code 39
Buffering Clear Buffer bar code or upon
attempt to transmit an empty Code 39
buffer.
Scan
Default Parameters on page
Reduce the number of ADF rules or the
number of steps in the ADF rules.
Normal.
Normal during host reset. Otherwise, set
the scanner's RS-232 parity to match the
host setting.
This occurs if a unit is not properly
configured. Check option setting.
Wait several seconds and scan again.