Symbol LS3008 Product Reference Guide
RS-232 Host Parameters
Various RS-232 hosts are set up with their own parameter default settings
Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, Olivetti, Omron, or terminal sets the defaults listed below.
Terminal Specific RS-232
Table 6-2
Parameter
Transmit Code ID No
Data Trans-
mission Format
Suffix
Baud Rate
Parity
Hardware
Handshaking
Software
Handshaking
Serial Response
Time-out
Stop Bit Select
ASCII Format
Beep On <BEL>
RTS Line State
Prefix
*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar
codes.
**If Nixdorf Mode B is scanned without the scanner connected to the proper host, it may appear
unable to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power to
the scanner.
Standard
ICL
(Default)
Yes
Yes
Data as is Data/Suffix
Data/Suffix Data/Suffix
CR/LF
CR (1013)
CR (1013)
(7013)
9600
9600
9600
None
Even
None
None
RTS/CTS
None
Option 3
None
None
None
2 Sec.
9.9 Sec.
2 Sec.
One
One
One
8-Bit
8-Bit
8-Bit
Disable
Disable
Disable
Low
High
Low
None
None
None
Wincor-
Fujitsu
Nixdorf
Mode A
Yes
Yes
Data/Suffix
CR (1013)
CR (1013)
9600
9600
Odd
Odd
RTS/CTS
RTS/CTS
Option 3
Option 3
None
None
9.9 Sec.
9.9 Sec.
One
One
8-Bit
8-Bit
Disable
Disable
Low
Low = No data
to send
None
None
(Table
6-2). Selecting the ICL, Fujitsu,
Wincor-
Nixdorf
Olivetti
Mode B/
OPOS
Yes
Prefix/Data/
Suffix
ETX (1002) CR (1013)
9600
Even
None
Ack/Nak
9.9 Sec.
One
7-Bit
Disable
Low
STX (1003) None
Omron
Yes
Data/Suffix
9600
None
None
None
9.9 Sec.
One
8-Bit
Disable
High