Leading Margin (Quiet Zone) - Motorola Symbol LS3008 Product Reference Manual

Hide thumbs Also See for Symbol LS3008:
Table of Contents

Advertisement

Leading Margin (Quiet Zone)

Scan a bar code below to select a leading margin duration. A leading margin is the time that precedes the first bar
of the scan, (in milliseconds). The minimum allowed value is 80 msec and the maximum is 250 msec. This
parameter accommodates older wand decoders which cannot handle short leading margins.
1
NOTE
250 msec is the maximum value that this parameter can attain, however, 200 msec is sufficient.
*
80 msec
200 msec
Wand Emulation Interface
140 msec
9 - 5

Advertisement

Table of Contents
loading

Table of Contents