10 - 6 Symbol LS3008 Product Reference Guide

Convert Newer Code Types

The scanner supports a variety of code types that are not decodable by attached decoder systems. To allow
compatibility in these environments, the scanner converts these code types to more commonly decodable
symbologies, as per the following chart. Symbologies not listed on this chart are transmitted normally.
Scan this code type:
Code 11
Chinese 2 of 5
GS1 DataBar (14, Limited, and Expanded)
Coupon Code
When decoding these code types with this parameter disabled, the scanner issues Convert Error beeps and
transmits no data.
*
Convert Newer Code Types

Module Width

The standard module width is 20 µs. For an extremely slow decoder system, select 50 µs Module Width.
*
20 µs Module Width
Transmitted as:
Code 39
Code 39
Code 128
Code 128
Reject Newer Code Types
50 µs Module Width