Convert Newer Code Types

The digital scanner supports a variety of code types that are not decodable by attached decoder systems. To
allow compatibility in these environments, the digital scanner converts these code types to more commonly
decodable symbologies, as per the following chart. Symbologies not listed on this chart transmit normally.
Code 11
GS1 DataBar (14, Limited, and Expanded), Coupon Code, PDF, MicroPDF,
MaxiCode, Data Matrix, QR Code, Postal Codes, Composite Codes
When decoding these code types with this parameter disabled, the digital scanner issues Convert Error beeps
and transmits no data. The amount of data in the scanned newer bar code type should not exceed that of the
conversion code type.
*Convert Newer Code Types

Module Width

The standard module width is 20 µs. For an extremely slow decoder system, select 50 µs Module Width.
*20 µs Module Width
Scan this Code Type:
Scanner Emulation Interface 10 - 7
Transmitted as:
Code 39
Code 128
Reject Newer Code Types
50 µs Module Width