Convert Newer Code Types; Module Width - Motorola Symbol DS6708 Product Reference Manual

Motorola symbol ds6708 digital scanner product reference guide
Hide thumbs Also See for Symbol DS6708:
Table of Contents

Advertisement

11 - 6 Symbol DS6708 Digital Scanner Product Reference Guide

Convert Newer Code Types

The digital scanner supports a variety of code types that are not decodable by attached decoder systems. To allow
compatibility in these environments, the digital scanner converts these code types to more commonly decodable
symbologies, as per the following chart. Symbologies not listed on this chart are transmitted normally.
Code 11
GS1 DataBar (14, Limited, and Expanded), Coupon Code, PDF, MicroPDF,
MaxiCode, DataMatrix, QR Code, Postal Codes, Composite Codes
When decoding these code types with this parameter disabled, the digital scanner issues Convert Error beeps and
transmits no data. The amount of data in the scanned newer bar code type should not exceed that of the
conversion code type.
*Convert Newer Code Types

Module Width

The standard module width is 20 µs. For an extremely slow decoder system, select 50 µs Module Width.
*20 µs Module Width
Scan this Code Type:
Transmitted as:
Code 39
Code 128
Reject Newer Code Types
50 µs Module Width

Advertisement

Table of Contents
loading

Table of Contents