Lamp Abnormality - Christie DS+750 Service Manual

Multimedia projector
Hide thumbs Also See for DS+750:
Table of Contents

Advertisement

Troubleshooting

Lamp Abnormality

The Lamp Driving Circuit
AC
K6A
F901
SW901
POWER(AC)
FUSE
MAINS
SWITCH
BALLAST_AC1
BALLAST_AC2
IC4401
LAMP2_ON
COLOR
LAMP2_RXD
MANAGEMENT
FPGA
LAMP2_TXD
<EP3C40F484>
LAMP1_ON
LAMP1_RXD
LAMP1_TXD
IC1801
I/O
DC_ON
EXPANDER
<TE7783>
IC301
SYSTEM
CONTROL
<PW392>
NOTE :
At first, the high-voltage pulse (about 8KVp-p) is generated between the
lamp electrodes to generate glow discharge. Then dielectric breakdown
occurs, finally glow discharge comes to arc discharge.
After projector turned on, 30 seconds are required until the light output
stabilizes.
After the projector is turned off, the cooling fans operate for 90 seconds to
cool down the lamp and reduce gas pressure inside the lamp.
NOTE :
Switch
Lamp Cover
Make sure that the lamp cover is mounted correctly. If not or the lamp cover
removed, the lamp does not light for safety.
Check the boss of the lamp cover and the lamp cover switch (SW902).
SW902 -- open : Abnormality
Thermal Switches
When the internal temperature near the lamps reaches near 80ºC, the
temperature switches open and 12V is not supplied to PFC1-2 board, also
the Power fail signal "PF_POWER" bocomes "Low".
SW903 - SW904 -- open : Abnormality
POWER (green) LED indicates lamp monitor operation
LED off:
Lamp is being cooled.
LED on:
Lamp is being lit or already cooled down.
K6B
PFC12V
PF_POWER
K6C
K66B
K66N
POWER(DC)
PFC_ON
ST_SW
K66L
K8B
Check that the lamp power
drive signals (PFC_ON1,
PFC_ON2) are correct.
Power-On: H
31
X1A
CN4
CN1
BALLAST1
12V
X2A
CN6
PFC_ON1
PFC1-2
PFC_ON2
CN3
X1B
BALLAST2
X2B
K8L
IC4731
Q4731
IC4701
Q4701
SS3.3V
PFC_ON
ST_SW
IC5808
CPU : ---- Lamp monitor operation ----
The CPU performs an input check by the lamp monitor
pin (LAMP_RX).
When the "H" signal continues 1 second or more con-
tinuously, the CPU judges the state to be abnormal.
When it has detected abnormal condition, the CPU
turns off a projector compulsorily. And the CPU sets up
the cooling time for 90 seconds.
The projector cannot be turned on during a cooling
time.
-135-
Check that the lamp on/
off signals (LAMP1_ON,
LAMP2_ON) are correct.
Lamp-On: H
X3A
LAMP1
LP901
LAMP ID
X3B
LAMP2
LP902
LAMP ID
K8Q
K8Z
LAMPA_1_ID
LAMPA_2_ID
ID I/F 1
LAMPA_3_ID
K8Y
LAMPB_1_ID
LAMPB_2_ID
ID I/F 2
LAMPB_3_ID
If the Lamp ID board is not mounted
securely, the warning message will
appear on the screen and some func-
tions may be disabled.
DS+750 Service Manual